Related Experiment Video
Updated: Jun 21, 2025

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
Published on: December 27, 2012
Engineering the Blackbody Absorption of the Au-Branch-on-Au-Plate Heterostructures
Jin Ji1, Junsheng Wang1, Tingting Jiang1
1Institute of Advanced Synthesis (IAS), School of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, China.
Abstract:
Utilizing the strong ligand control effects of l-cysteine (l-Cys), the growth of Au on Au triangular nanoplate (AuTN) seeds was continuously tuned from layer-by-layer (the Frank-van der Merwe) to layer-plus-island (the Stranski-Krastanov), and island (the Volmer-Weber) growth modes, leading to the formation of a series of Au-on-AuTN heterostructures. Within the window of VW growth mode (featured by the growth of Au spikes and branches on AuTNs), the effective localized surface plasmon resonance (LSPR) coupling led to the selective strengthening of the "valley" absorptions, leading to smooth and flat absorption curves. Interestingly, through engineering the number/density, size, and branching degree of the Au branches, except for the black color, full spectrum absorption within 400-1300 nm wavelength was achieved on Au-branch-on-AuTN structures. Mechanistic studies revealed that the blackbody absorption property of the Au-branch-on-AuTN originates from the well-balanced intraparticle LSPR couplings among the neighboring Au branches. The tunable blackness and the full spectrum absorption property made the Au-branch-on-AuTN heterostructure a suitable candidate for various plasmonic-related applications, such as a wide spectrum light absorber, photoacoustic imaging contrast agent, and photothermal therapy medium. In addition, our strong ligand control in Au-branch-on-AuTN heterostructures could be extended to other hybrid systems with diverse material combinations, so long as to find the proper strong ligand.
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...

