Collection efficiencies of cylindrical and plane parallel ionization chambers: analytical and numerical results and

John D Fenwick1, Sudhir Kumar2, Juan Pardo-Montero3,4

  • 1Department of Medical Physics and Bioengineering, 8th Floor, Malet Place Engineering Building, University College London, Gower Street, London WC1E 6BT, England, United Kingdom.

PubMed

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
586
Spherical and Cylindrical Capacitor01:26

Spherical and Cylindrical Capacitor

A spherical capacitor consists of two concentric conducting spherical shells of radii R1 (inner shell) and R2 (outer shell). The shells have  equal and opposite charges of +Q and −Q, respectively. For an isolated conducting spherical capacitor, the radius of the outer shell can be considered to be infinite.
Conventionally, considering the  symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
5.6K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
696
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
434
Gauss's Law: Cylindrical Symmetry01:20

Gauss's Law: Cylindrical Symmetry

A charge distribution has cylindrical symmetry if the charge density depends only upon the distance from the axis of the cylinder and does not vary along the axis or with the direction about the axis. In other words, if a system varies if it is rotated around the axis or shifted along the axis, it does not have cylindrical symmetry. In real systems, we do not have infinite cylinders; however, if the cylindrical object is considerably longer than the radius from it that we are interested in,...
7.6K
Column Efficiency: Plate Theory01:10

Column Efficiency: Plate Theory

Band broadening in a chromatography column is measured by its efficiency. This is determined by the number of theoretical plates (N). Theoretical plate theory states that a separation column consists of a continuous series of imaginary plates where solute equilibration occurs between stationary and mobile phases.
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
571