Related Experiment Video
Updated: Jun 21, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Comparison of the Shear Bond Strength Using Primers with Different Application Numbers on Dental Zirconia
Suphakit Opatragoon1, Awiruth Klaisiri2, Tool Sriamporn3
1Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Objective:
This study examined the effect of the number of phosphate-containing primer applications on the shear bond strength (SBS) of zirconia to resin cement.
Materials And Methods:
315 square specimens (10 × 10 × 4 mm3) were manufactured from Cercon ht presintered zirconia blocks. Alumina particles were used to sandblast zirconia specimens. These specimens were randomly divided into six primer-based groups: No primer application (NP), CLEARFIL CERAMIC PRIMER (C), PANAVIA V5 Tooth Primer (T), M&C PRIMER (MC), Monobond N (MN), and Z-PRIME plus (Z), and then separated into application number (1-4) groups (excluding NP). Each specimen was bonded with resin cement. The SBS was measured using a universal testing machine. The debonded surface was examined with a stereomicroscope.
Statistical Analysis:
The SBSs were analyzed using two-way analysis of variance.
Results:
Applying the primer twice exhibited the highest SBSs in each group, with significant differences in the T, MN, and Z groups. However, the SBS in the MC group was significantly lower on the second application. One-hundred percent adhesive failure was observed in all groups.
Conclusion:
Within the limitations of this study, prior to cementation, the sandblasted zirconia surface should be applied twice with a phosphate-containing primer other than MC to maximize the SBS at the zirconia-resin cement interface.
More Related Videos
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
08:45Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014