Related Experiment Video
Updated: Aug 1, 2026

Modified Drop Tower Impact Tests for American Football Helmets
Published on: February 19, 2017
A comparison of sub-concussive impact attenuating capabilities of ice hockey helmets with and without XRD foam
Hannah N Emerson1, Tina L Claiborne1, Victor Liberi1
1Department of Exercise Science & Athletic Training, Adrian College, United States of America.
Objectives:
To compare the impact attenuating capabilities between ice hockey helmets manufactured with and without XRD impact protection foam, worn with and without a XRD skullcap, at reducing sub-concussive head accelerations.
Design:
Quasi-experimental laboratory.
Methods:
Ice hockey helmets were fit onto a Hybrid III 50th Head Form Head and dropped 25 times onto the left temporal side for each condition: XRD foam helmet, XRD foam helmet with XRD skullcap adjunct, non-XRD foam helmet, and non-XRD foam helmet with XRD skullcap adjunct. The helmets were dropped from a height that resulted in sub-concussive linear accelerations (25-80 g's). Using a tri-axial accelerometer, peak linear accelerations (g) were measured, and the average was used to compare impact attenuation properties across the four conditions.
Results:
The highest linear accelerations were observed in the XRD foam helmet without skullcap (32.97 ± 0.61 g) and were significantly greater (p < 0.001) than the XRD helmet with skullcap (21.38 ± 0.76 g). The helmet without XRD foam elicited the lowest peak linear accelerations (16.10 ± 0.73 g) which were significantly lower than the XRD foam helmet regardless of whether the skullcap was added (p < 0.001).
Conclusions:
Although sub-concussive loads are potentially just as dangerous, much of the research regarding helmet and skullcap efficacy appears to be at high concussive impacts; <70 g's. The findings suggest that helmets with incorporated XRD foam, either within the design or added as an adjunct, are less effective at attenuating linear accelerations at sub-concussive levels than the low-density foam helmet.