Related Experiment Video
Updated: Jun 21, 2025

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Incisura tangent method to determine the transsyndesmotic axis for syndesmotic fixation
Toshinari Mashu1, Satoshi Yamaguchi2, Seiji Kimura1
1Graduate School of Medical and Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba-shi, Chiba 260-8670, Japan.
Background:
Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods.
Methods:
We analyzed computed tomographic images of 43 normal ankles. The IT view was simulated using a digitally reconstructed radiograph, in which the anterior and posterior fibular incisura tubercles overlapped on the internally rotated anteroposterior view. The interaxis angle between the TS and the axes determined by the IT method was measured on the axial computed tomographic image corresponding to the radiographic image. The same procedure was repeated using the CC and TL methods. The measured values were compared between the three methods using a one-factor analysis of variance. Furthermore, the measurements of the anteverted and retroverted incisurae were compared for each fluoroscopic method.
Results:
The mean interaxis angles between the TS were - 0.5 degrees, 6.3 degrees, and - 1.8 degrees for the IT, CC, and TL methods, respectively, with a significantly larger value for the CC method than for the IT and TL methods (P < .001). No significant difference was found in the interaxis angle in the anteverted (-0.1 degrees) and retroverted (-1.0 degrees) incisurae when using the IT method (P = .15). The angles in the retroverted incisurae were larger than those of the anteverted incisurae for the CC and TL methods.
Conclusion:
The fluoroscopic IT method accurately estimated the TS axis. The interaxis angles were consistent, regardless of the incisura anatomy. The fluoroscopic method can be used to clamp and fix the syndesmosis along the TS axis.
Level Of Evidence:
Ⅳ.
More Related Videos
Related Concept Videos
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
Method of Joints: Problem Solving I
Method of Joints: Problem Solving II
Adjusting a Traverse
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...

