ARDSFlag: an NLP/machine learning algorithm to visualize and detect high-probability ARDS admissions independent of
Amir Gandomi1,2, Phil Wu3, Daniel R Clement4
1Frank G. Zarb School of Business, Hofstra University, Hempstead, NY, USA. amir.gandomi@hofstra.edu.
Background:
Despite the significance and prevalence of acute respiratory distress syndrome (ARDS), its detection remains highly variable and inconsistent. In this work, we aim to develop an algorithm (ARDSFlag) to automate the diagnosis of ARDS based on the Berlin definition. We also aim to develop a visualization tool that helps clinicians efficiently assess ARDS criteria.
Methods:
ARDSFlag applies machine learning (ML) and natural language processing (NLP) techniques to evaluate Berlin criteria by incorporating structured and unstructured data in an electronic health record (EHR) system. The study cohort includes 19,534 ICU admissions in the Medical Information Mart for Intensive Care III (MIMIC-III) database. The output is the ARDS diagnosis, onset time, and severity.
Results:
ARDSFlag includes separate text classifiers trained using large training sets to find evidence of bilateral infiltrates in radiology reports (accuracy of 91.9%±0.5%) and heart failure/fluid overload in radiology reports (accuracy 86.1%±0.5%) and echocardiogram notes (accuracy 98.4%±0.3%). A test set of 300 cases, which was blindly and independently labeled for ARDS by two groups of clinicians, shows that ARDSFlag generates an overall accuracy of 89.0% (specificity = 91.7%, recall = 80.3%, and precision = 75.0%) in detecting ARDS cases.
Conclusion:
To our best knowledge, this is the first study to focus on developing a method to automate the detection of ARDS. Some studies have developed and used other methods to answer other research questions. Expectedly, ARDSFlag generates a significantly higher performance in all accuracy measures compared to those methods.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
