Related Experiment Video
Updated: Jun 20, 2025

Measurements of Soil Carbon by Neutron-Gamma Analysis in Static and Scanning Modes
Published on: August 24, 2017
Neutron spectrum measurements near KAMINI reactor south beam vault door using nested neutron spectrometer
D Venkata Subramanian1, Adish Haridas1, D Sunil Kumar1
1Reactor Shielding and Data Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, India.
Abstract:
KAlpakkam MINI reactor (KAMINI) is a 233U fuelled research reactor has various neutron irradiation locations for experimental purposes. The pit at the south beam end of KAMINI reactor is being extensively utilised for neutron attenuation experiments in prospective shielding materials as well as for neutron radiography. During reactor operation, it will be closed by a movable shield. A vault door is located above the shield and the movable shield is used to attenuate streaming neutrons and gamma-rays during reactor operation. Even with the shield, there exists significant dose because of streaming neutrons and gamma rays. Its variation depends on the power of the reactor. The neutron and gamma dose rates close to the south beam vault door have recently been found to be 275-300 μSv/h and 175-200 μSv/h, respectively, when the reactor is operating at 10 kW. In order to characterise the streaming neutron spectra of vault door place for the first time, measurements are done using the Nested Neutron Spectrometer. Along with the neutron flux, neutron mean energy and ambient dose-equivalent rate are also measured and compared with earlier measurements carried out inside the south beam pit. It is observed that the presence of paraffin shield reduces the neutron average energy from 370 to 178 keV. Apart from energy reduction, 10 kW normalised neutron flux of south beam pit is also attenuated by the shield by 25 000 times and it is found that the neutron spectrum of the measured location is also more thermalized. Neutron reference data of the location are generated.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
08:48High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
Published on: April 28, 2022
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Lab
Nuclear Binding Energy
Nuclear Fission
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Nuclear Stability
To hold positively charged protons together...