Related Experiment Video
Updated: Jun 20, 2025

Extraction and Analysis of Microbial Phospholipid Fatty Acids in Soils
Published on: August 26, 2016
A configuration for cooling assisted organic solvent coated thin film microextraction after dispersive liquid-liquid
Mohammad R Rezayat1, Mohammad T Jafari1, Leila Mohammadipour1
1Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
Abstract:
A combination of the dispersive liquid-liquid microextraction (DLLME) method based on the total vaporization procedure and cooling-assisted organic solvent-coated thin film microextraction (TFME) was applied for extracting chlorpyrifos (as the model compound). Based on the high thermal conductivity, a nickel foam thin film with the dimensions of 5.0 mm × 5.0 mm was used as a substrate for holding the organic solvent. Supporting thin film by organic solvent increases the thickness and contact area of the film relative to TFME or single drop microextraction (SDME) alone, resulting in a dramatic increase in the extraction efficiency. To protect the organic solvent and enhance the analyte distribution coefficient between the film and the vapor phase, a cooling system was applied. The proposed design was effective due to condensing the target analyte only on the uniform cooled thin film and not on the other regions in the extraction chamber. A corona discharge ionization source-ion mobility spectrometer was employed to identify the analyte. After optimizing the effective parameters, the limits of quantification (S/N = 10) and detection (S/N = 3) were calculated 0.1 and 0.03 μg L-1, respectively, and the dynamic range was measured between 0.1 and 7.0 μg L-1, with a determination coefficient of 0.9997. For three concentration levels of 0.1, 3.0, and 7.0 μg L-1, the relative standard deviations (n = 3) as the repeatability index were to be 6 %, 5 %, and 4 % for intra-day and 9 %, 6 %, and 5 % for inter-day, respectively. The enrichment factor was also calculated to be 3630 for the analyte concentration of 1.0 μg L-1. Well water, potato, and agricultural wastewater were analyzed as the real samples and the relative recovery values were measured between 92 % and 99 %. The accuracy of the proposed technique was validated by the European Standards EN 12393 method. In this approach, two steps of analyte extraction (DLLME and TFME) were used consecutively, resulting in better preconcentration and reduced matrix interference during cleaning-up.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Extraction: Advanced Methods
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
High-Performance Liquid Chromatography: Elution Process
Preparation of Samples for Electron Microscopy
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...