Changes in Intratumor Blood Flow After Carbon-Ion Radiation Therapy for Early-Stage Breast Cancer
Kenta Ohmatsu1, Tokuhiko Omatsu2, Noriyuki Okonogi2,3
1Department of Radiation Oncology, Tokyo Women's Medical University School of Medicine, Tokyo, Japan.
Purpose:
This study aimed to quantify the changes in intratumoral blood flow after carbon-ion radiation therapy (CIRT) for early-stage breast cancer and analyze their clinical significance.
Patients And Methods:
We included 38 patients with early-stage breast cancer who underwent CIRT. Dynamic imaging was performed using a 3T superconducting magnetic resonance scanner to quantify the washin index (idx), which reflects contrast uptake, and washout idx, which reflects the rate of contrast washout from tumor tissue. The changes in the apparent diffusion coefficient, washin idx, and washout idx were examined before CIRT and at 1 and 3 months after treatment. Clinical factors and imaging features were examined using univariate and receiver operating characteristic curve analyses to identify factors predicting clinical complete response (cCR).
Results:
The median observation period after CIRT was 51 (range: 12-122) months. During the observation period, 31 of the 38 patients achieved cCR, and 22 achieved cCR within 12 months. Tumor size (P < .001), washin idx (P = .043), and washout idx (P < .001) decreased significantly 1-month after CIRT. In contrast, the apparent diffusion coefficient values (P < .001) increased significantly 1-month after CIRT. Univariate analysis suggested that the washin idx after 1 and 3 months of CIRT was associated with cCR by 12 months post-CIRT (P = .028 and .021, respectively). No other parameters were associated with cCR by 12 months post-CIRT. Furthermore, receiver operating characteristic curve analyses showed that the area under the curve values of washin idx after 1 and 3 months of CIRT was 0.78 (specificity 75%, sensitivity 80%) and 0.73 (specificity 75%, sensitivity 71%), respectively.
Conclusion:
Tumor changes can be quantified early after CIRT using contrast-enhanced magnetic resonance imaging in patients with breast cancer. Washin idx values 1 and 3 months after CIRT were associated with cCR within 12 months post-CIRT.
Related Concept Videos
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...