Related Experiment Video
Updated: May 9, 2026

Deep Neuromuscular Blockade Leads to a Larger Intraabdominal Volume During Laparoscopy
Published on: June 25, 2013
Modified Thoracoabdominal Nerves Block Through Perichondral Approach: A Systematic Review and Meta-analysis
Insun Park1, Jae Hyon Park2, Chang-Hoon Koo3
1Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi, Republic of Korea; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicines, Seoul, Republic of Korea.
Purpose:
This systematic review and meta-analysis aimed to investigate the postoperative analgesic efficacy and safety of the modified thoracoabdominal nerve block through the perichondral approach (M-TAPA) in abdominal surgeries.
Design:
Systematic review and meta-analysis.
Methods:
We searched electronic databases to identify relevant studies comparing M-TAPA with conventional analgesic techniques. The primary outcome was the requirement for rescue analgesia at 12 and 24 hours postsurgery. Secondary outcomes included the 11-point numerical rating scale pain scores at 0, 1, 2, 4, 6, 8, 12, and 24 hours following surgery, global quality of recovery scores, and postoperative adverse events.
Findings:
Five randomized controlled trials involving 308 patients were analyzed. M-TAPA showed no significant difference in the requirement for rescue analgesia at 12 hours (relative risk [RR]: 0.87; 95% confidence interval [CI]: 0.62, 1.22; P = .424; I2 = 40.7%; Ph = .185) and 24 hours (RR: 0.67; 95% CI: 0.22, 1.99; P = .252; I2 = 90.3%; Ph < .001) postsurgery compared to non-M-TAPA. No significant differences in numerical rating scale pain scores or global quality of recovery scores were found between the two groups (all P < .05). However, M-TAPA was associated with a lower occurrence of nausea (RR: 0.37; 95% CI: 0.22, 0.68; P < .001; I2 = 0%; Ph = .834), vomiting (RR: 0.32; 95% CI: 0.17, 0.62; P < .001; I2 = 0%; Ph = .884), and itching (RR: 0.38; 95% CI: 0.21, 0.70; P = .002; I2 = 0%; Ph = .826).
Conclusions:
There was no significant difference in analgesic efficacy and safety between M-TAPA and non-M-TAPA techniques.