A developed DQ control method for shunt active power filter to improve power quality in transformers
Saad F Al-Gahtani1, Z M S Elbarbary1, Shaik Mohammad Irshad1
1Electrical Engineering Department, College of Engineering, King Khalid University, Abha, Saudi Arabia.
Abstract:
Power transformers are the most important component in power system. Exposing these transformers to the harmonic distortions causes additional heat losses, insulation stress, decrease in lifetime of insulation, and reduced power factor with decrease in efficiency of the system. The lifespan of distribution transformers is influenced by the fragility of power quality in power networks. Harmonic mitigation filters with robust control technique are required to reduce the harmonic effects on power transformer. Traditionally, synchronous reference frame (DQ) is employed to control the shunt active power filter (APF) for mitigation of harmonics in power transformers. DQ control of Shunt APF lacks merits of fast response, delayed operation due to phased lock loop under abnormal grid conditions leading to insufficient harmonic elimination. A developed DQ method based on detecting the positive and negative sequence components is proposed to precisely control the shunt APF for reliable operation of power transformer. This detection technique improves the response time, mitigate the harmonics effecting the operation of transformer and overall power factor. The proposed control system is evaluated under different abnormal operating scenarios and compared with traditional DQ method. The results and analysis confirm the efficacy of the developed DQ method in improving the power transformer performance.
More Related Videos
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Control of Power Flow
Power Factor Correction
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Fast Decoupled and DC Powerflow