Pericardial tamponade after laparoscopic repair of a giant diaphragmatic hernia
Maciej Dębski1,2, Abbas Sardar3, Craig Vickery4
1Cardiology Department, West Suffolk Hospitals NHS Trust, Bury Saint Edmunds, UK maciekdebski@gmail.com.
Abstract:
Laparoscopic intraperitoneal onlay mesh repair is favoured for diaphragmatic hernias due to better outcomes. However, fixation devices pose risks, including cardiac tamponade. A man underwent laparoscopic repair for a large diaphragmatic hernia. One week later, he presented with chest discomfort which was initially attributed to postoperative pain. Subsequently, patient represented with worsening of chest pain and tachycardia. CT requested to rule out pulmonary embolism revealed a large pericardial effusion. Urgent drainage via apical approach resolved tamponade. The case highlights the challenges in managing pericardial effusions post-laparoscopy in the presence of diaphragmatic mesh and stresses multidisciplinary collaboration. Literature review highlights risks associated with fixation devices. Suggestions include limiting their use near vital structures. Key learning point of this case report is to raise awareness of cardiac tamponade following diaphragmatic hernia repair. Limited evidence necessitates cautious use of fixation devices, emphasising patient safety.