Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder
Published on: March 4, 2018
Hybridized deep learning goniometry for improved precision in Ehlers-Danlos Syndrome (EDS) evaluation
Thirumalesu Kudithi1, J Balajee2, R Sivakami3
1School of Technology, The Apollo University, Chittoor, India.
Background:
Generalized Joint Hyper-mobility (GJH) can aid in the diagnosis of Ehlers-Danlos Syndrome (EDS), a complex genetic connective tissue disorder with clinical features that can mimic other disease processes. Our study focuses on developing a unique image-based goniometry system, the HybridPoseNet, which utilizes a hybrid deep learning model.
Objective:
The proposed model is designed to provide the most accurate joint angle measurements in EDS appraisals. Using a hybrid of CNNs and HyperLSTMs in the pose estimation module of HybridPoseNet offers superior generalization and time consistency properties, setting it apart from existing complex libraries.
Methodology:
HybridPoseNet integrates the spatial pattern recognition prowess of MobileNet-V2 with the sequential data processing capability of HyperLSTM units. The system captures the dynamic nature of joint motion by creating a model that learns from individual frames and the sequence of movements. The CNN module of HybridPoseNet was trained on a large and diverse data set before the fine-tuning of video data involving 50 individuals visiting the EDS clinic, focusing on joints that can hyperextend. HyperLSTMs have been incorporated in video frames to avoid any time breakage in joint angle estimation in consecutive frames. The model performance was evaluated using Spearman's coefficient correlation versus manual goniometry measurements, as well as by the human labeling of joint position, the second validation step.
Outcome:
Preliminary findings demonstrate HybridPoseNet achieving a remarkable correlation with manual Goniometric measurements: thumb (rho = 0.847), elbows (rho = 0.822), knees (rho = 0.839), and fifth fingers (rho = 0.896), indicating that the newest model is considerably better. The model manifested a consistent performance in all joint assessments, hence not requiring selecting a variety of pose-measuring libraries for every joint. The presentation of HybridPoseNet contributes to achieving a combined and normalized approach to reviewing the mobility of joints, which has an overall enhancement of approximately 20% in accuracy compared to the regular pose estimation libraries. This innovation is very valuable to the field of medical diagnostics of connective tissue diseases and a vast improvement to its understanding.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Margin of Error
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...