Related Experiment Video
Updated: Jun 20, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Minimal dose CT for left ventricular ejection fraction and combination with chest-abdomen-pelvis CT
Martin Weber Kusk1,2,3, Søren Hess3,4, Oke Gerke4,5
1Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland.
Objectives:
This prospective study tested the diagnostic accuracy, and absolute agreement with MRI of a low-dose CT protocol for left ventricular ejection fraction (LVEF) measurement. Furthermore we assessed its potential for combining it with Chest-Abdomen-Pelvis CT (CAP-CT) for a one-stop examination.
Materials & Methods:
Eighty-two patients underwent helical low-dose CT. Cardiac magnetic resonance imaging (MRI) was the reference standard. In fifty patients, CAP-CT was performed concurrently, using a modified injection protocol. In these, LVEF was measured with radioisotope cardiography (MUGA). Patients >18 years, without contrast media or MRI contraindications, were included. Bias was measured with Bland-Altman analysis, classification accuracy with Receiver Operating Characteristics, and inter-reader agreement with Intra-Class Correlation Coefficient (ICC). Correlation was examined using Pearson's correlation coefficients. CAP image quality was compared to previous scans with visual grading characteristics.
Results:
The mean CT dose-length-product (DLP) was 51.8 mGycm, for an estimated effective dose of 1.4 mSv, compared to 5.7 mSv for MUGA. CT LVEF bias was between 2 % and 10 %, overestimating end-diastolic volume. When corrected for bias, sensitivity and specificity of 100 and 98.5 % for classifying reduced LVEF (50 % MRI value) was achieved. ICC for MUGA was significantly lower than MRI and CT. Distinction of renal medulla and cortex was reduced in the CAP scan, but proportion of diagnostic scans was not significantly different from standard protocol.
Conclusion:
When corrected for inter-modality bias, CT classifies patients with reduced LVEF with high accuracy at a quarter of MUGA dose and can be combined with CAP-CT without loss of diagnostic quality.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...