Related Experiment Video
Updated: Jun 20, 2025

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Augmented Biphasic Breathing Using Sniff and an Oral Positive Expiratory Pressure Device (Sniff-PEP) in Fontan
Shawn Shaji1, Muhammad A Zafar2, Adam Christopher1
1Department of Pediatrics, Heart Institute, UPMC Children's Hospital of Pittsburgh, University of Pittsburgh School of Medicine, 4401 Penn Avenue, Pittsburgh, PA, 15224, USA.
Abstract:
The use of an oral positive expiratory pressure device (oPEP) with sniff breathing (Sniff-PEP) mimics biphasic ventilation. Biphasic ventilation increases pulmonary blood flow and cardiac output in Fontan patients. The aim of this study was to assess the effect of Sniff-PEP on Fontan flow velocities. A single-center, pilot, prospective study was carried out in 15 subjects with Fontan circulation enrolled to use the oPEP device for 1 month. Subjects were instructed on Sniff-PEP and to use the device for 10-15 min 3-4 times a day. Measurements of flow velocity and cardiac output were measured via echocardiogram and quality of life assessments were performed at baseline and 4-6 weeks later. The mean age at enrollment was 19.9 ± 8.7 years (age range of 10-37 years). 7 patients (47%) had dominant left ventricle and 8 (53%) had an open fenestration. There was a statistically significant increase in flow velocities in the hepatic vein from 27.5 ± 7.6 to 35.1 ± 11.3 cm/s (p = 0.003), left pulmonary artery from 51.6 ± 16.6 to 57.6 ± 21.1 cm/s (p = 0.01), and right pulmonary artery from 43.1 ± 14.2 to 45.8 ± 17.2 cm/s (p = 0.04). With chronic use, the mean fenestration gradient slightly decreased from 4.5 ± 1.6 to 4.1 ± 1.9 mmHg but the difference was not statistically significant (p = 0.14). oPEP device therapy increased flow velocity in several areas in the Fontan circulation with acute use. Further studies are needed to assess the effects long term.Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT03251742.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...

