Related Experiment Video
Updated: Jun 20, 2025

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Prospective observational study of 2 wearable strain sensors for measuring the respiratory rate
Hiroki Sato1, Tatsuya Nagano1, Shintaro Izumi2
1Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Hyogo, Japan.
Abstract:
The respiratory rate is an important factor for assessing patient status and detecting changes in the severity of illness. Real-time determination of the respiratory rate will enable early responses to changes in the patient condition. Several methods of wearable devices have enabled remote respiratory rate monitoring. However, gaps persist in large-scale validation, patient-specific calibration, standardization and their usefulness in clinical practice has not been fully elucidated. The aim of this study was to evaluate the accuracy of 2 wearable stretch sensors, C-STRECH® which is used in clinical practice and a novel stretchable capacitor in measuring the respiratory rate. The respiratory rate of 20 healthy subjects was measured by a spirometer with the stretch sensor applied to 1 of 5 locations (umbilicus, lateral abdomen, epigastrium, lateral chest, or chest) of their body at rest while they were in a sitting or supine position before or after exercise. The sensors detected the largest amplitudes at the epigastrium and umbilicus compared to other sites of measurement for the sitting and supine positions, respectively. At rest, the respiratory rate of the sensors had an error of 0.06 to 2.39 breaths/minute, whereas after exercise, an error of 1.57 to 3.72 breaths/minute was observed compared to the spirometer. The sensors were able to detect the respiratory rate of healthy volunteers in the sitting and supine positions, but there was a need for improvement in detection after exercise.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...

