Real-time monitoring of gradient chromatography using dual Kalman-filters
Gusten Zandler-Andersson1, Daniel Espinoza1, Niklas Andersson1
1Division of Chemical Engineering, Department of Process and Life Science Engineering, Lund University, Lund, Sweden.
Abstract:
Real-time state estimation in chromatography is a useful tool to improve monitoring of biopharmaceutical downstream processes, combining mechanistic model predictions with real-time data acquisition to obtain an estimation that surpasses that of either approach individually. One common technique for real-time state estimation is Kalman filtering. However, non-linear adsorption isotherms pose a significant challenge to Kalman filters, which are dependent on fast algorithm execution to function. In this work, we apply Kalman filtering of non-constant elution conditions using a non-linear adsorption isotherm using a novel approach where dual Kalman filters are used to estimate the states of the adsorption modifier, salt, and the components to be separated. We performed offline tuning of the Kalman filters on real chromatogram data from a linear gradient, ion-exchange separation of two proteins. The tuning was then validated by running the Kalman filters in parallel with a chromatographic separation in real time. The resulting, tuned, dual Kalman filters improved the L2 norm by 53 % over the open-loop model prediction, when compared to the true elution profiles. The Kalman filters were also applicable in real-time with a signal sampling frequency of 5 s, enabling accurate and robust estimation and paving the way for future applications beyond monitoring, such as real-time optimal pooling control.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:24Generation of Heterogeneous Drug Gradients Across Cancer Populations on a Microfluidic Evolution Accelerator for Real-Time Observation
Published on: September 19, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
High-Performance Liquid Chromatography: Instrumentation
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...