Related Experiment Video
Updated: Jun 20, 2025

Homogeneous Time-resolved Förster Resonance Energy Transfer-based Assay for Detection of Insulin Secretion
Published on: May 10, 2018
Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples
Lei Zhou1, Ruifeng Zhu2, Gabriela Figueroa-Miranda2
1Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany; Faculty I, RWTH Aachen University, Aachen, Germany.
Background:
Diabetes patients suffer either from insulin deficiency or resistance with a high risk of severe long-term complications, thus the quantitative assessment of insulin level is highly desired for diabetes surveillance and management. Utilizing insulin-capturing aptamers may facilitate the development of affordable biosensors however, their rigid G-quadruplex structures impair conformational changes of the aptamers and diminish the sensor signals.
Results:
Here we report on a ratiometric, electrochemical insulin aptasensor which is achieved by hybridization of an insulin-capturing aptamer and a partially complementary ssDNA to break the rigid G-quadruplex structures. To improve the durability of the aptasensor, the capturing aptamer was immobilized on gold electrodes via two dithiol-phosphoramidite functional groups while methoxy-polyethylene glycol thiol was used as a blocking molecule. The exposure of the sensor to insulin-containing solutions induced the dissociation of the hybridized DNA accompanied by a conformational rearrangement of the capturing aptamer back into a G-quadruplex structure. The reliability of sensor readout was improved by the adoption of an AND logic gate utilizing anthraquinone and methylene blue redox probes associated to the aptamer and complementary strand, respectively. Our aptasensor possessed an improved detection limit of 0.15 nM in comparison to aptasensors without strand displacement.
Significance:
The sensor was adapted for detection in real blood and is ready for future PoC diagnostics. The capability of monitoring the insulin level in an affordably manner can improve the treatment for an increasing number of patients in developed and developing nations. The utilization of low-cost and versatile aptamer receptors together with the engineering of ratiometric electrochemical signal recording has the potential to considerably advance the current insulin detection technology toward multi-analyte diabetes sensors.