Related Experiment Video
Updated: Jun 24, 2026

Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
A Lateral Flow Biosensor Based on Isothermal Amplification for Visual Identification of Species and Sex from
Huyun Zhou1,2, Wenjing Hu1,2, Jiaxing Zhang3
1School of Forensic Medicine, Shanxi Medical University, Taiyuan 030001, China.
Abstract:
The prompt species identification from biological samples at a crime scene can rapidly filter out truly valuable biometric information for subsequent personal identification. Meanwhile, early sex determination can assist in narrowing the pool of suspects. However, the current methods for forensic DNA analysis, particularly in point-of-care scenarios, are often limited by the intricate equipment for signal generation and the laborious procedure for DNA purification. The present study introduces a novel portable lateral flow biosensor that possesses extraction-free and anti-aerosol characteristics for on-site determination of species and sex. The bloodstain can be directly submitted to loop-mediated isothermal amplification (LAMP) for the analysis of both mitochondrial and nuclear DNA. The incorporation of a lateral flow device with gold magnetic nanoparticle probes allows for visual interpretation of results through colorimetric signals while also preventing interference on result judgment from pigments such as hemoglobin. Carryover contamination, which is a disharmonious factor in LAMP, especially as the inherent contradiction derived from uncapping in the lateral flow strategy, has been effectively addressed through the integration of uracil DNA glycosylase without compromising the isothermy throughout the process. As a proof-of-concept experiment, species and sex can be accurately identified within 40 min from trace bloodstains amidst significant background interference by targeting cytochrome b and Y-chromosomal amelogenin. Furthermore, the single-blind study revealed a concordance rate of up to 100% in both simulative degraded and true dated bloodstains. This suggests that this biosensor has the potential to be utilized in forensic DNA analysis at crime scenes.
More Related Videos
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
07:13Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Rapid Identification of Pathogens