Related Experiment Video
Updated: Jun 20, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Enhanced Internal Dosimetry for Alimentary Tract Organs in Nuclear Medicine based on the ICRP Mesh-Type Reference
Tae-Eun Kwon1, Haegin Han1, Chansoo Choi2
1Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850, United States of America.
Abstract:
This study introduces a refined approach for more accurately estimating radiation doses to alimentary tract organs in nuclear medicine, by utilizing the ICRP pediatric and adult mesh-type reference computational phantoms (MRCPs) that improved the anatomical representation of these organs. Our initial step involved compiling a comprehensive dataset of electron Specific Absorbed Fractions (SAFs) for all source-target pairs of alimentary tract organs in both adult and pediatric phantoms, calculating SAFs for all cases in the present study only except those computed in the previous study for certain pediatric phantom cases. Subsequently, we determined S values for 1,252 radionuclides, facilitating dosimetry applications. The consistency of target and source masses for alimentary tract organs in the MRCPs with the reference values in ICRP Publication 89 led to noticeable differences in SAF, S values, and consequently, absorbed dose coefficients when compared to the stylized models in ICRP Publication 100. Notably, the S value ratios (MRCP/stylized) for selected radionuclides-11C, 18F, 68Ga, and 131I-ranged from 0.41 to 7.60. Particularly for therapeutic 131I-iodide in thyroid cancer, the use of MRCPs resulted in up to 1.49 times higher absorbed dose coefficients for the colon than those derived from stylized models, while the stomach dose coefficients decreased by a factor of 0.72. The application of our findings promises enhanced, more realistic dosimetry for alimentary tract organs, especially beneficial for radiopharmaceuticals likely to accumulate within these organs.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET