Related Experiment Video
Updated: Jun 20, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
A comparison of two piezoelectric actuator concepts for fast mechanical switching in DC hybrid circuit breakers
Mohmmad Al-Dweikat1, Guogang Zhang1, Yu Liu1
1State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.
Abstract:
Amplified piezoelectric actuators have gained considerable attention due to their inherent advantages, including rapid response, reliability, and efficiency, making them promising candidates for Direct Current (DC) switching applications. They can operate in two distinct operational modes: Block-Free (B-F) and Free-Free (F-F) configurations. These two modes offer diverse mechanical constraints and are chosen based on the application's specific requirements. This study aims to present a comparative assessment between the two modes to evaluate each configuration's applicability in DC fast switching. Accordingly, the principle behind each actuation scheme was illustrated, and both designs were modeled and analyzed by the finite element method. Subsequently, two prototypes were assembled, each resembling a different operational mode. The established prototypes were then subjected to actuation and interruption tests to investigate their travel and switching performances. Comparative results revealed that while block-free could deliver a higher apparent stroke, the accumulated gap for each configuration is almost the same. Both actuators demonstrated high capability when utilized as actuation units for fast vacuum mechanical switches integrated into a hybrid circuit breaker for DC interruption. However, the free-free operation excelled in terms of fast response, as it managed to clear the mimicked fault current faster than the block-free configuration.
Related Concept Videos
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Directional Relays
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...