Mid-term outcomes using a 'kinematic retaining' total knee replacement - A multicentre prospective study at five
Michael D Wilson1, Suraj Kohli1, James O Smith2
1Department of Orthopaedics, University Hospitals Dorset NHS Foundation Trust, The Royal Bournemouth Hospital, Castle Lane East, Bournemouth, Dorset, BH7 7DW, UK.
This study shows the novel kinematic retaining knee implant provides excellent patient outcomes and survivorship in total knee replacement surgery. The Physica KR implant demonstrates high satisfaction and functional improvement over five years.
Area of Science:
- Orthopedic Surgery
- Biomedical Engineering
- Clinical Outcomes Research
Background:
- Total knee replacement (TKR) aims to improve pain and deformity but patient satisfaction varies.
- A novel 'kinematic retaining' (KR) implant was developed to address incomplete patient outcomes.
- This study evaluates the survivorship and clinical efficacy of the KR implant.
Purpose of the Study:
- To assess the survivorship, clinical, and radiological outcomes of the Physica KR implant.
- To evaluate patient-reported outcomes and satisfaction following TKR with the KR implant.
- To determine the long-term effectiveness of kinematic retaining knee prostheses.
Main Methods:
- Prospective study of 156 patients undergoing TKR for primary osteoarthritis using the Physica KR implant.
- Five-year follow-up including radiographic and clinical evaluations.
- Assessment of Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Oxford Knee Score (OKS), Visual Analogue Score (VAS) for satisfaction, and Forgotten Joint Score (FJS).
Main Results:
- High good-excellent clinical and functional KSS scores (79.4%-85.9% at 6 months, maintained at 76.9%-79.5% at 5 years).
- Significant improvements in KSS, KOOS, OKS, VAS satisfaction, and FJS were observed and maintained at 5 years.
- No progressive adverse radiographic features noted; low revision rate (2/156) for infection and aseptic loosening.
Conclusions:
- The novel kinematic retaining knee prosthesis demonstrates exceptional clinical and patient-reported improvements.
- The Physica KR implant shows a remarkable 99.4% survivorship at five years.
- This implant offers a promising solution for improving total knee replacement outcomes.