Related Experiment Video
Updated: May 5, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Can plethysmographic capillary refill time predict lactate during sepsis? An observational study from Morocco
Chadi Rahmani1,2, Ayoub Belhadj1,2, Younes Aissaoui1,2
1Department of Emergency and Intensive Care Medicine, Avicenna Military Hospital, Marrakech, Morocco.
Visual capillary refill time (V-CRT) accurately predicts lactate levels in septic patients, offering a valuable alternative where blood lactate testing is unavailable. This study found V-CRT to be a reliable indicator of tissue perfusion and hypoxia in critical care settings.
Area of Science:
- Critical Care Medicine
- Emergency Medicine
- Clinical Physiology
Background:
- Blood lactate is a key marker for tissue hypoxia and guiding resuscitation in sepsis.
- Capillary refill time (CRT) assesses tissue perfusion but faces challenges in precision and reproducibility.
- Blood lactate measurement is often unavailable in resource-limited African emergency departments.
Purpose of the Study:
- To evaluate the accuracy of visual capillary refill time (V-CRT) compared to plethysmographic CRT (P-CRT) in predicting arterial lactate levels in septic patients.
- To determine if P-CRT offers improved accuracy over V-CRT in this clinical context.
Main Methods:
- A prospective observational study involving 43 patients with sepsis or septic shock.
- Simultaneous measurements of V-CRT, P-CRT, and arterial lactate levels upon admission.
- ROC curve analysis to assess the precision of V-CRT and P-CRT in predicting arterial lactate.
Main Results:
- Both V-CRT and P-CRT showed significant correlations with arterial lactate (r=0.529 and r=0.517, respectively).
- V-CRT demonstrated satisfactory accuracy in predicting lactate levels >2 mmol/l (AUC=0.8), outperforming P-CRT (AUC=0.73).
- Optimal thresholds were 3.4s for V-CRT (sensitivity 90%) and 4.1s for P-CRT (sensitivity 85%).
Conclusions:
- Plethysmographic CRT did not enhance the accuracy of CRT for predicting lactate levels compared to visual assessment.
- V-CRT serves as a viable and accurate surrogate for lactate measurement in septic patients, particularly in low-income settings.
- V-CRT can aid in assessing circulatory status and guiding resuscitation when lactate testing is not feasible.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024