Related Experiment Video
Updated: Aug 7, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Siam-VAE: A hybrid deep learning based anomaly detection framework for automated quality control of head CT scans
Soumyendu Sekhar Ghosh1, Rajat Dhar2, Daniel S Marcus3
1Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO, USA.
Abstract:
An automated quality control (QC) system is essential to ensure streamlined head computed tomography (CT) scan interpretations that do not affect subsequent image analysis. Such a system is advantageous compared to current human QC protocols, which are subjective and time-consuming. In this work, we aim to develop a deep learning-based framework to classify a scan to be of usable or unusable quality. Supervised deep learning models have been highly effective in classification tasks, but they are highly complex and require large, annotated data for effective training. Additional challenges with QC datasets include - 1) class-imbalance - usable cases far exceed the unusable ones and 2) weak-labels - scan level labels may not match slice level labels. The proposed framework utilizes these weak labels to augment a standard anomaly detection technique. Specifically, we proposed a hybrid model that consists of a variational autoencoder (VAE) and a Siamese Neural Network (SNN). While the VAE is trained to learn how usable scans appear and reconstruct an input scan, the SNN compares how similar this input scan is to its reconstruction and flags the ones that are less similar than a threshold. The proposed method is more suited to capture the differences in non-linear feature structure between the two classes of data than typical anomaly detection methods that depend on intensity-based metrics like root mean square error (RMSE). Comparison with state-of-the-art anomaly detection methods using multiple classification metrics establishes superiority of the proposed framework in flagging inferior quality scans for review by radiologists, thus reducing their workload and establishing a reliable and consistent dataflow.
More Related Videos
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022