Related Experiment Video
Updated: Jun 19, 2025

Author Spotlight: Point-of-Care Ultrasound for Gastric Content Assessment and Risk Stratification in Perioperative Care
Published on: September 22, 2023
Optimal bowel diameter thresholds for diagnosing small bowel obstruction and surgical intervention with point-of-care
Hamid Shokoohi1, Nour Al Jalbout1, Gary D Peksa2
1Department of Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States of America.
Objectives:
A bowel diameter threshold of ≥2.5 cm, originally derived from the research using computed tomography, is frequently used for diagnosing small bowel obstruction (SBO) with point-of-care ultrasound (POCUS). We sought to determine the optimal bowel diameter threshold for diagnosing SBO using POCUS and its accuracy in predicting surgical intervention.
Methods:
We conducted a secondary analysis using individual patient-level data from a previous systematic review on POCUS for SBO diagnosis across five academic EDs. Patient data were collected, including imaging results, surgical findings, and final diagnosis. The measured diameter of the small bowel using POCUS was recorded. ROC area under the receiver operating characteristic curves (AUC) were constructed to determine the optimal threshold for bowel diameter in predicting SBO diagnosis and surgical intervention. Subgroup analyses were performed based on sex and age.
Results:
A total of 403 patients had individual patient-level data available, with 367 patients included in the final analysis. The most accurate bowel diameter overall for predicting SBO was 2.75 cm (AUC = 0.76, 95% CI 0.71-0.81). A bowel diameter of ≤1.7 cm had 100% sensitivity with no miss rate, while a bowel diameter of ≥4 cm had 90.7% specificity in confirming SBO. Patients under 65 had an optimal threshold of 2.75 cm versus 2.95 cm in patients over 65. Females had an optimal threshold of 2.75 cm, while males had a value of 2.95 cm. There was no significant correlation between bowel diameter thresholds and surgical intervention.
Conclusion:
A bowel diameter threshold of 2.75 cm on POCUS is more discriminative diagnostic accuracy for diagnosing SBO. Patients' age and sex may impact diagnostic accuracy, suggesting that tailored approaches may be needed.
Related Concept Videos
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...

