Related Experiment Video
Updated: Jun 19, 2025

A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
Published on: June 21, 2017
Pulse generators for enhanced magnetomotive ultrasound: Toward a cost-effective imaging for tissue characterization
Ernesto E Mazon Valadez1,2, Ricardo R Bordonal2, José E Freire2
1Technology Science Department, Universidad de Guadalajara, Centro Universitario de la Ciénega, Ocotlan, Jalisco 47810, Mexico.
Abstract:
Magnetomotive ultrasound (MMUS) stands out as a promising and effective ultrasound-based method for detecting magnetic nanoparticles (MNPs) within tissues. This innovative technique relies on the precise estimation of micrometric displacements induced by the interaction of an external magnetic field with MNPs. Pulsed MMUS has emerged as a strategic alternative to address limitations associated with harmonic excitation, such as heat generation in amplifiers and coils, frequency-dependent tissue mechanical responses, and prolonged magnetic field rise times. Despite the growing interest in MMUS, the devices conventionally employed to excite the coil are not specifically tailored to generate intense magnetic fields while minimizing interference with the transient behavior of induced displacements. To bridge this gap, our work introduces the design and fabrication of two pulse generators: one based on a capacitor-discharge circuit and the other on a resonant-inverter circuit. We evaluated the performance of these pulse generators by considering parameters such as the magnetic field generated, rise and fall times, and their ability to supply sustained current for varied pulse widths across different pulse repetition frequencies. Furthermore, we carried out a practical MMUS implementation using tissue-mimicking phantoms, demonstrating the capability of both devices to achieve magnetic fields of up to 1 T and average displacements of 25 µm within the phantom. In addition, we estimated the shear wave velocity, effective shear modulus, and their temperature-dependent variations. Our findings highlight the versatility and efficacy of the proposed pulse generators and emphasize their potential as low-cost platforms for theranostic applications, enabling the assessment of targeted entities within biological tissues.
More Related Videos
13:41Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Published on: January 13, 2023
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Magnetic Resonance Imaging
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences