Contrast-enhanced mammography versus conventional imaging in women recalled from breast cancer screening (RACER
Lidewij M F H Neeter1,2, Patricia J Nelemans3, H P J Raat4
1Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, P.O. Box 5800, 6202AZ, Maastricht, the Netherlands.
Background:
Women recalled from breast cancer screening receive post-screening work-up in the hospital with conventional breast imaging. The RACER trial aimed to study whether contrast-enhanced mammography (CEM) as primary imaging instead of conventional imaging resulted in more accurate and efficient diagnostic work-up in recalled women.
Methods:
In this randomised, controlled trial (registered under NL6413/NTR6589) participants were allocated using deterministic minimisation to CEM or conventional imaging as a primary work-up tool in two general and two academic hospitals. Predefined patients' factors were reason for recall, BI-RADS score, and study centre. Primary outcomes were sensitivity and specificity. Secondary outcomes were the proportion of women needing supplemental examinations, and number of days until diagnosis.
Findings:
Between April, 2018, and September, 2021, 529 patients recalled from the Dutch screening program were randomised, 265 to conventional imaging and 264 to CEM. Three patients in the control arm had to be excluded from analysis due to a protocol breach. After the entire work-up, sensitivity was 98.0% (95% CI; 92.2-99.7%) in the intervention arm and 97.7% (91.8-99.6%) in the control arm (p = 1.0), and specificity was 75.6% (72.5-76.6%) and 75.4% (72.5-76.4%, p = 1.0), respectively. Based on only primary full-field digital mammography/digital breast tomosynthesis or CEM, final diagnosis was reached in 27.7% (73/264) in the intervention arm and 1.1% (3/262) in the control arm. The frequency of supplemental imaging was significantly higher in the control arm (p < 0.0001). Median time needed to reach final diagnosis was comparable: 1 day (control arm: IQR 0-4; intervention arm: IQR 0-3). Thirteen malignant occult lesions were detected using CEM, versus three using conventional imaging. No serious adverse events occurred.
Interpretation:
Diagnostic accuracy of CEM in the work-up of recalled women is comparable with conventional imaging. However, work-up with CEM as primary imaging is a more efficient pathway.
Funding:
ZonMw (grant number 843001801) and GE Healthcare.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...