Related Experiment Video
Updated: Jun 19, 2025

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Soft x-ray diagnostics system for electron temperature measurement in the integrated commissioning phase of JT-60SA
Ryuichi Sano1, Hiroto Homma1, Manabu Takechi1
1Naka Institute, National Institutes for Quantum Science and Technology, Naka 311-0193, Japan.
Abstract:
A soft x-ray (SX) diagnostic system has been designed and installed in JT-60SA for the first plasma. For quantitative measurement, the etendue of each viewing chord was evaluated analytically and numerically. The electron temperature is evaluated from the detected bremsstrahlung emission ratio between two detector arrays with two different thicknesses of Be filters. The two filter thicknesses were optimized to be 7 and 50 μm for the expected electron temperature range of 0-3 keV. The one-dimensional profile of SX emission is reconstructed from line integrated emission by the elliptic Abel inversion scheme. For a plasma discharge with a plasma current of 1 MA, a peaked electron temperature profile with about 800 eV at the center is obtained. The total bremsstrahlung power was also evaluated using the electron temperature profile and the absolutely evaluated etendue of each viewing chord. In this evaluation, the bremsstrahlung power is around 10% of ohmic heating power.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
X-ray Imaging
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...