Related Experiment Video
Updated: Jun 19, 2025

Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions
Published on: September 7, 2018
Investigation of induced electroosmotic flow in small-scale capillary electrophoresis devices: Strategies for control
Miyuru De Silva1, Prabhavie M Opallage1, Robert C Dunn1
1Department of Chemistry, Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas, USA.
Abstract:
Electroosmotic flow (EOF) is the bulk flow of solution in a capillary or microchannel induced by an applied electric potential. For capillary and microchip electrophoresis, the EOF enables analysis of both cations and anions in one separation and can be varied to modify separation speed and resolution. The EOF arises from an electrical double layer at the capillary wall and is normally controlled through the pH and ionic strength of the background buffer or with the use of additives. Understanding and controlling the electrical double layer is therefore critical for maintaining acceptable repeatability during method development. Surprisingly, in fused silica capillaries at low pH, studies observe an EOF even though the capillary surface should be neutralized. Previous work has suggested the presence of an "induced electroosmotic flow" from radial electric fields generated across the capillary wall due to the separation voltage and grounded components external to the capillary. Using thin-wall (15 µm) fused silica separation capillaries to facilitate the study of radial fields, we show that the EOF mobility depends on both the separation voltage and the location of external grounds. This is consistent with the induced EOF model, in which radial electric fields embed positive charges at the capillary walls to create an electrical double layer. The magnitude of the effect is characterized and shown to have long-range influences that are difficult to completely null by moving grounded components away from the separation capillary. Instead, active EOF control using externally applied potentials or a passive approach using a negative separation voltage are discussed as two possible methods for controlling the induced EOF. Both methods can reverse the EOF and improve the resolution and peak efficiency in amino acid separations.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Controlled-Current Coulometry: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
High-Performance Liquid Chromatography: Elution Process