Multicenter, international study of CT practices and radiation doses from 10 African countries: An International
Giridhar Dasegowda1, Miriam Mikhail Lette2, Stacy Achoki3
1Massachusetts General Hospital and Harvard Medical School, Boston, US; Mass General Brigham Data Science Office, Boston, US.
Purpose:
The objective of our IAEA-coordinated international study was to assess CT practices and radiation doses from multiple hospitals across several African countries.
Methods:
The study included 13 hospitals from Africa which contributed information on minimum of 20 consecutive patients who underwent head, chest, and/or abdomen-pelvis CT. Prior to the data recording step, all hospitals had a mandatory one-hour training on the best practices in recording the relevant data elements. The recorded data elements included patient age, weight, protocol name, scanner information, acquisition parameters, and radiation dose descriptors including phase-specific CT dose index volume (CTDIvol in mGy) and dose length product (DLP in mGy.cm). We estimated the median and interquartile range of body-region specific CTDIvol and DLP and compared data across sites and countries using the Kruskal-Wallis H Test for non-normal distribution, analysis of variance.
Results:
A total of 1061 patients (mean age 50 ± 19 years) were included in the study. 16 % of CT exams had no stated clinical indications for CT examinations of the head (32/343, 9 %), chest (50/281, 18 %), abdomen-pelvis (67/243, 28 %), and/or chest-abdomen-pelvis CT (24/194, 12 %). Most hospitals used multiphase CT protocols for abdomen-pelvis (9/11 hospitals) and chest CT (10/12 hospitals), regardless of clinical indications. Total median DLP values for head (953 mGy.cm), chest (405 mGy.cm), and abdomen-pelvis (1195 mGy.cm) CT were above the UK, German, and American College of Radiology Diagnostic Reference Levels (DRLs).
Conclusions:
Concerning variations in CT practices and protocols across several hospitals in Africa were demonstrated, emphasizing the need for better protocol optimization to improve patient safety.
More Related Videos
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...