Exploring accurate mass measurements in pixel-based chemometrics: Advancing coffee classification with GC-HRMS-A
Andre Cunha Paiva1, Carlos Alberto Teixeira1, Leandro Wang Hantao1
1Institute of Chemistry, University of Campinas, 270 Monteiro Lobato, Campinas, SP 13083-862, Brazil; National Institute of Science and Technology in Bioanalytics (INCTBio), SP, Campinas, 13083-862 Brazil.
Abstract:
This paper presents a study that assesses the application of chemometrics for classifying coffee samples in a quality control context. High-resolution and accurate mass measurements were utilized as input for pixel-based orthogonal partial least squares discriminant analysis (OPLS-DA) models. The compositional data were acquired through a fully automated workflow combining headspace solid-phase microextraction and gas chromatography-high-resolution mass spectrometry (GC-HRMS) using an FT-Orbitrap® mass analyzer. A workflow centered on accurate mass measurements was successfully utilized for group-type analysis, offering an alternative to methods relying solely on MS similarity searches. The predictive models underwent thorough evaluation, demonstrating robust multivariate classification performance. Five key coffee attributes, bitterness, acidity, body, intensity, and roasting level were successfully predicted using GC-HRMS data. The results revealed strong predictive accuracy across all models, ranging from 88.9 % (bitterness) to 94.4 % (roasting level). This study represents a significant advancement in automating methods for coffee quality control, notably increasing the predictive ability of the models compared to existing literature.
More Related Videos
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...