Bacterial counts on fabrics: a comparative study of three methods.

J Hoborn, B Nyström

    The Journal of Hygiene
    |October 1, 1985
    PubMed
    Summary

    Assessing bacterial contamination on fabrics requires effective methods. Homogenization techniques, particularly using a Stomacher 400, are more efficient than the contact plate method for bacterial counting.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Usefulness of discography, discoblock and a new mechanical method for identifying a painful segment/disc.

    Neuro-Chirurgie·2022
    Same author

    Out-of-hospital cardiac arrest: Causes according to autopsy and electrocardiography - Analysis of 781 patients with neither hospital care nor prescribed medication during the preceding two years.

    Resuscitation·2020
    Same author

    [The Medical Officers Association of Finland during the 30 year period 1921-50].

    Sotilaslaaketieteellinen aikakauslehti·2014
    Same author

    Tadalafil increases muscle capillary recruitment and forearm glucose uptake in women with type 2 diabetes.

    Diabetologia·2010
    Same author

    A technique for simultaneous sampling of cerebrospinal and brain extracellular fluid in unanaesthetized rabbits.

    Neurochemistry international·2010
    Same author

    Changes of extracellular proteins in hippocampus during depolarization.

    Neurochemistry international·2010

    Area of Science:

    • Microbiology
    • Textile Science

    Background:

    • Bacterial contamination of fabrics is a concern in various settings.
    • Accurate enumeration of bacteria on textiles is crucial for quality control and safety.

    Purpose of the Study:

    • To compare the efficiency of the contact plate method with two homogenization methods for assessing bacterial contamination on fabrics.
    • To identify the most practical and effective method for bacterial enumeration on textile surfaces.

    Main Methods:

    • Comparison of bacterial counts obtained using the contact plate method.
    • Evaluation of two distinct homogenization techniques for bacterial recovery from fabrics.
    • Utilizing a Stomacher 400 for one of the homogenization procedures.

    Main Results:

    • The contact plate method yielded significantly lower bacterial counts compared to both homogenization methods.
    • The two homogenization methods produced comparable bacterial counts.
    • The Stomacher 400 homogenization method was identified as more practical.

    Conclusions:

    • Homogenization methods are superior to the contact plate method for assessing bacterial contamination on fabrics.