Occlusal force transfer by removable partial denture designs for a radical maxillectomy.
The Journal of Prosthetic Dentistry
|September 1, 1985
Summary
Physiologically adjusted removable partial denture retainers significantly reduce stress on supporting structures. Optimized I-bar retainers best transfer forces, while some designs concentrate stress in the premolar region.
Area of Science:
- Dental prosthetics
- Biomaterials engineering
- Biomechanics
Background:
- Surgical resection of the maxilla presents challenges for removable partial denture (RPD) rehabilitation.
- Understanding stress distribution from RPD retainers is crucial for long-term success and patient comfort.
- Photoelastic analysis offers a method to visualize stress patterns in dental models.
Purpose of the Study:
- To evaluate and compare the stress distribution of various removable partial denture retainer designs.
- To assess the impact of physiologic adjustment on stress reduction in RPD frameworks.
- To identify optimal retainer designs for stress management in post-maxillary resection patients.
Main Methods:
- Testing multiple RPD retainer designs on a photoelastic cast of a surgically resected human maxilla.
- Utilizing photoelastic stress analysis to visualize and quantify stress concentrations under load.
- Comparing stress patterns between physiologically adjusted and unadjusted RPD frameworks.
Main Results:
- Physiologic adjustment dramatically reduced stresses when frameworks were in place.
- Adjusted frameworks produced less damaging stress in supporting structures compared to unadjusted ones.
- High stresses were consistently observed in the premolar region across all designs.
- Lingual retainers generated higher stress concentrations than buccal retainers.
- The I-bar retainer with a cingulum rest proved most effective for anterior force transmission.
Conclusions:
- Physiologic adjustment is critical for minimizing stress in RPD frameworks.
- Infrabulge I-bar retainers (buccal or lingual) offer the most equitable stress transfer.
- Light wire circumferential and cast circumferential swing-lock retainers show less favorable stress distribution.