Related Experiment Video
Updated: Jun 19, 2025

Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
The surgical interval between robot-assisted SEEG and epilepsy resection surgery is an influencing factor of SSI
Xiaolian Xie1,2, Hongwu Yao1, Hulin Zhao3
1Department of Infection Management and Disease Control, Chinese PLA General Hospital, The 1st Medical Center, Fuxing Road No. 28, Beijing, 100853, China.
Background:
In recent years, the development of robotic neurosurgery has brought many benefits to patients, but there are few studies on the occurrence of surgical site infection (SSI) after robot-assisted stereoelectroencephalography (SEEG). The purpose of this study was to collect relevant data from robot-assisted SEEG over the past ten years and to analyze the influencing factors and economic burden of surgical site infection.
Methods:
Basic and surgical information was collected for all patients who underwent robot-assisted SEEG from January 2014 to December 2023. Logistic regression was used to analyze the factors influencing SSI according to different subgroups (radiofrequency thermocoagulation or epilepsy resection surgery).
Results:
A total of 242 subjects were included in this study. The risk of SSI in the epilepsy resection surgery group (18.1%) was 3.5 times greater than that in the radiofrequency thermocoagulation group (5.1%) (OR 3.49, 95% CI 1.39 to 9.05); this difference was statistically significant. SSI rates in the epilepsy resection surgery group were associated with shorter surgical intervals (≤ 9 days) and higher BMI (≥ 23 kg/m2) (6.1 and 5.2 times greater than those in the control group, respectively). Hypertension and admission to the intensive care unit (ICU) were risk factors for SSI in the radiofrequency thermocoagulation group. Patients with SSIs had $21,231 more total hospital costs, a 7-day longer hospital stay, and an 8-day longer postoperative hospital stay than patients without SSI.
Conclusions:
The incidence of SSI in patients undergoing epilepsy resection after stereoelectroencephalography was higher than that in patients undergoing radiofrequency thermocoagulation. For patients undergoing epilepsy resection surgery, prolonging the interval between stereoelectroencephalography and epilepsy resection surgery can reduce the risk of SSI; At the same time, for patients receiving radiofrequency thermocoagulation treatment, it is not recommended to enter the ICU for short-term observation if the condition permits.