Nasal High-Frequency Oscillatory Ventilation Use in Romanian Neonatal Intensive Care Units-The Results of a Recent
Maria Livia Ognean1,2, Anca Bivoleanu3, Manuela Cucerea4
1Faculty of Medicine, Lucian Blaga University, 550169 Sibiu, Romania.
Background:
Nasal high-frequency oscillatory ventilation (nHFOV) has emerged as an effective initial and rescue noninvasive respiratory support mode for preterm infants with respiratory distress syndrome (RDS); however, little is known about nHFOV use in Romanian neonatal intensive care units (NICUs).
Objectives:
We aimed to identify the usage extent and clinical application of nHFOV in Romania.
Methods:
A structured web-based questionnaire was designed to find the rate of nHFOV use and knowledge of this new method of noninvasive respiratory support in Romanian level III NICUs. Using multiple-choice, open-ended, and yes/no questions, we collected information on the NICU's size, noninvasive respiratory support modes used, nHFOV use, indications, settings, nasal interfaces, secondary effects, and equipment used. Descriptive statistics and comparisons were performed using IBM SPSS Statistics 26.0.
Results:
A total of 21/23 (91.3%) leaders from level III NICUs (median [IQR] number of beds of 10 [10-17.5]) responded to the survey. The most frequently used noninvasive ventilation modes were CPAP mode on mechanical ventilators (76.2%), followed by NIPPV (76.2%); heated, humidified high-flow nasal cannula (HHHFNC) (61.9%); and nHFOV (11/21 units; 52.4%). A total of 5/11 units reported frequent nHFOV use (in two or more newborns/month) in both term and preterm infants. The main indications reported for nHFOV use were CPAP failure (90.9%), hypercapnia (81.8%), and bronchopulmonary dysplasia (72.7%). Face/nasal masks and short binasal prongs are the most commonly used nasal interfaces (90.9% and 72.7%, respectively). Air leaks at the interface level (90.9%), thick secretions (81.8%), and airway obstruction (63.6%) were the most frequently mentioned adverse effects of nHFOV. Only three of the NICUs had a written protocol for nHFOV use. Most units not yet using nHFOV cited lack of equipment, experience, training, or insufficient information and evidence for the clinical use and outcome of nHFOV use in neonates as the main reasons for not implementing this noninvasive respiratory mode.
Conclusions:
Our survey showed that nHFOV is already used in more than half of the Romanian level III NICUs to support term and preterm infants with respiratory distress despite a lack of consensus regarding indications and settings during nHFOV.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation I: Indication and Settings