Related Experiment Video
Updated: Jun 19, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Comparison of Metabolic Control in Children and Adolescents Treated with Insulin Pumps
Agnieszka Lejk1, Karolina Myśliwiec1, Arkadiusz Michalak2,3
1Department of Pediatrics, Diabetology and Endocrinology, Medical University of Gdansk, 80-210 Gdansk, Poland.
Background:
While insulin pumps remain the most common form of therapy for youths with type 1 diabetes (T1DM), they differ in the extent to which they utilize data from continuous glucose monitoring (CGM) and automate insulin delivery.
Methods:
The aim of the study was to compare metabolic control in patients using different models of insulin pumps. This retrospective single-center study randomly sampled 30 patients for each of the following treatments: Medtronic 720G without PLGS (predictive low glucose suspend), Medtronic 640G or 740G with PLGS and Medtronic 780G. In the whole study group, we used CGM systems to assess patients' metabolic control, and we collected lipid profiles. In three groups of patients, we utilized CGM sensors (Guardian 3, Guardian 4, Libre 2 and Dexcom G6) to measure the following glycemic variability proxy values: time in range (TIR), time below 70 mg/dL (TBR), time above 180 mg/dL (TAR), coefficient of variation (CV) and mean sensor glucose.
Results:
Medtronic 640G or 740G and 780G users were more likely to achieve a target time in the target range 70-180 mg/dL (≥80%) [Medtronic 720G = 4 users (13.3%) vs. Medtronic 640G/740G = 10 users (33.3%) vs. Medtronic 780G = 13 users (43.3%); p = 0.0357)] or low glucose variability [Medtronic 720G = 9 users (30%) vs. Medtronic 640G/740G = 18 users (60%) vs. Medtronic 780G = 19 users (63.3%); p = 0.0175)].
Conclusions:
Any integration between the insulin pump and CGM was associated with better glycemic control. More advanced technologies and artificial intelligence in diabetes help patients maintain better glycemia by eliminating various factors affecting postprandial glycemia.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes Mellitus: Type 2 and Gestational
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...