Numerical Investigation of Reinforced Concrete (RC) Columns Strengthened with Ultra-High-Performance Fiber-Reinforced

Andreas Lampropoulos1, Spyridon Paschalis2, Ourania Tsioulou1

  • 1School of Architecture, Technology and Engineering, University of Brighton, Cockcroft Building, Lewes Road, Brighton BN2 4GJ, UK.

PubMed

Related Concept Videos

Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
209
Method of Sections: Problem Solving I01:27

Method of Sections: Problem Solving I

Consider a symmetrical roof truss structure, composed of vertical, diagonal, and horizontal members. The length of each horizontal member is 4 m. The lengths of the vertical members FB and HD are 4 m, while the length of member GC is 6 m. The loads acting at joints F, G, and H are 2 kN, while those at joints A and E are 1 kN.
542
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
208
Euler's Formula to Columns with Other End Conditions01:15

Euler's Formula to Columns with Other End Conditions

Euler's formula is very important in the field of structural engineering, providing a foundation for understanding the critical loading conditions of pin-ended columns. This formula links the modulus of elasticity, the moment of inertia of the cross-section, and the column's length, offering a precise calculation of the critical load at which a column is prone to buckling.
497
Comparison between RL and RC circuits01:24

Comparison between RL and RC circuits

An RC circuit consists of resistance and capacitance, while in an RL circuit, capacitance is replaced by an inductor. RL and RC circuits are first-order differential circuits that store energy. An RC circuit stores energy in the electric field, while an RL circuit stores energy in the magnetic field. When connected to a battery, an RC circuit charges the capacitor, causing the current to decrease from maximum to zero upon being fully charged. This increases the voltage across the capacitor from...
3.9K
Design of Columns under a Centric Load01:17

Design of Columns under a Centric Load

The design of columns under centric load is a fundamental aspect of structural engineering and is critical for ensuring the stability and integrity of structures. Euler's and Secant's formulas are central to understanding and calculating the critical load and deformation behaviors of columns, providing a basis for safe and effective structural design.
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
107