Related Experiment Video
Updated: May 13, 2026

An Injectable and Drug-loaded Supramolecular Hydrogel for Local Catheter Injection into the Pig Heart
Published on: June 7, 2015
Influence of the Acceptor Fluid on the Bupivacaine Release from the Prospective Intra-Articular Methylcellulose
Dorota Wójcik-Pastuszka1, Anna Frąk1, Witold Musiał1
1Department of Physical Chemistry and Biophysics, Faculty of Pharmacy, Wroclaw Medical University, ul. Borowska 211A, 55-556 Wrocław, Poland.
Abstract:
Injections are one way of delivering drugs directly to the joint capsule. Employing this possibility, local anesthetic, such as bupivacaine (Bu), in the form of the suspension can be administered. The aim of this work was to propose a methylcellulose-based hydrogel-incorporated bupivacaine for intra-articular injections and to study the release kinetics of the drug from the hydrogel to different acceptor media, reflecting the synovial fluid of a healthy joint and the synovial fluid of an inflamed joint. The drug release studies were performed employing the flow apparatus. The drug was released to four different acceptor fluids: phosphate buffer pH = 7.4 (PBS7.4), phosphate buffer pH = 6.8 (PBS6.8), phosphate buffer pH = 7.4 with the high-molecular-weight sodium hyaluronate (PBS7.4H), and phosphate buffer pH = 6.8 with the low-molecular-weight sodium hyaluronate (PBS6.8L). The investigation was carried out at the temperature of 37 °C. The absorbance of the Bu released was measured at the wavelength of 262 nm every 2 min for 24 h. The release profiles of Bu to the acceptor media PBS7.4, PBS6.8, PBS7.4H, and PBS6.8L were described best by the first-order kinetics and the second-order equation. According to these models, the release rate constants were the highest when Bu was released to the fluid PBS7.4 and were k1 = (7.20 ± 0.01) × 10-5 min-1 and k2 = (3.00 ± 0.04) × 10-6 mg-1 × min-1, respectively. The relative viscosity of the acceptor medium, its pH, and the addition of high-molecular-weight or low-molecular-weight sodium hyaluronate (HAH or HAL) to the acceptor fluid influenced the drug dissolution. The release of Bu into the medium reflecting healthy synovial fluid takes a different pattern from its release into the fluid of an inflamed joint.
More Related Videos
09:11Alternating Magnetic Field-Responsive Hybrid Gelatin Microgels for Controlled Drug Release
Published on: February 13, 2016
12:22Synthesis of Thermogelling PolyN-isopropylacrylamide-graft-chondroitin Sulfate Composites with Alginate Microparticles for Tissue Engineering
Published on: October 26, 2016
Related Concept Videos
The Extracellular Matrix
Inflammatory Response II: Inflammatory Exudate and Tissue Repair
The typical wound exudate is odorless, transparent, straw-colored, thin, and watery. Exudate, however, can differ depending on the state of wound healing. Likewise, the exudate's...
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...
Intracellular Signaling Affects Focal Adhesions
Some...
Phases of Wound Repair
Formation of Blood Clot
In case of deep injuries, trauma to blood vessels results in blood loss. In the meantime, phospholipids released from the ruptured endothelial cellular membrane are converted into arachidonic...
Extracellular Matrix