Related Experiment Video
Updated: Jun 18, 2025

The Use of High-resolution Infrared Thermography HRIT for the Study of Ice Nucleation and Ice Propagation in Plants
Published on: May 8, 2015
StarDICE II: Calibration of an Uncooled Infrared Thermal Camera for Atmospheric Gray Extinction Characterization
Kélian Sommer1, Bertrand Plez1, Johann Cohen-Tanugi1,2
1Laboratoire Univers et Particules de Montpellier, Université de Montpellier, Centre National de la Recherche Scientifique, F-34095 Montpellier, France.
Abstract:
The StarDICE experiment strives to establish an instrumental metrology chain with a targeted accuracy of 1 mmag in griz bandpasses to meet the calibration requirements of next-generation cosmological surveys. Atmospheric transmission is a significant source of systematic uncertainty. We propose a solution relying on an uncooled infrared thermal camera to evaluate gray extinction variations. However, achieving accurate measurements with thermal imaging systems necessitates prior calibration due to temperature-induced effects, compromising their spatial and temporal precision. Moreover, these systems cannot provide scene radiance in physical units by default. This study introduces a new calibration process utilizing a tailored forward modeling approach. The method incorporates sensor, housing, flat-field support, and ambient temperatures, along with raw digital response, as input data. Experimental measurements were conducted inside a climatic chamber, with a FLIR Tau2 camera imaging a thermoregulated blackbody source. The results demonstrate the calibration effectiveness, achieving precise radiance measurements with a temporal pixel dispersion of 0.09 W m-2 sr-1 and residual spatial noise of 0.03 W m-2 sr-1. We emphasize that the accuracy of scene radiance retrieval can be systematically affected by the camera's close thermal environment, especially when the ambient temperature exceeds that of the scene.
More Related Videos
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectrometers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Absorption of Radiation