Method of Equivalent Error as a Criterion of the Assessment of the Algorithms Used for Estimation of Synchrophasor
Malgorzata Binek1, Pawel Rozga1
1Institute of Electrical Power Engineering, Lodz University of Technology, Stefanowskiego 20, 90-537 Lodz, Poland.
Abstract:
The development of digital techniques in control engineering leads to the creation of innovative algorithms for measuring specific parameters. In the field of electric power engineering these parameters may be amplitude, phase and frequency of voltage or current occurring in the analyzed electric grid. Thus, the algorithms mentioned, applied in relation to the quoted parameters, may provide precise and reliable measurement results in the electric grid as well as ensure better grid monitoring and security. Signal analysis regarding its identification due to the type of interference is very difficult because the multitude of information obtained is very large. In order to indicate the best method for determining errors in measuring synchronous parameters of the measured current or voltage waveforms, the authors propose in this paper a new form of one error for all testing functions, which is called an equivalent error. This error is determined for each error's value defined in the applicable standards for each of selected 15 methods. The use of the equivalent error algorithm is very helpful in identifying a group of methods whose operation is satisfactory in terms of measurement accuracy for various types of disturbances (both in the steady state and in the dynamic state) that may occur in the power grid. The results are analyzed for phasor measurement unit (PMU) devices of class P (protection) and M (measurement).
More Related Videos
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
The Swing Equation
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque...