Related Experiment Video
Updated: Jun 18, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Effect of Ablation Energy Source on Outcomes of Slow Pathway Modification for AVNRT in Children
Maully J Shah1, Shankar Baskar2, Kevin F Kennedy3
1Division of Cardiology, Children's Hospital of Philadelphia, Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Background:
Selection of radiofrequency ablation (RF) or cryoablation (Cryo) for atrioventricular nodal re-entrant tachycardia (AVNRT) in children remains controversial due to a lack of contemporary comparison studies in this population.
Objectives:
This study sought to compare outcomes of RF and Cryo for AVNRT in the pediatric population.
Methods:
AVNRT ablation outcomes were retrospectively analyzed utilizing the National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry from April 2016 to March 2019. Data from subjects 1 to 21 years of age undergoing elective first-time slow pathway (SP) modification for AVNRT were included. Exclusion criteria included <1 year of age, congenital heart disease, and >1 ablation target. Cases were analyzed by ablation energy: 1) RF only; 2) Cryo only; 3) radiofrequency ablation switching to cryoablation (RF→Cryo); and 4) cryoablation switching to radiofrequency ablation (Cryo→RF). The primary outcome was acute ablation failure. Secondary outcomes included in-hospital adverse events.
Results:
Among 2,448 patients (mean age 13.6 ± 3.4 years, 60% female), RF only was employed in 43% (n = 1,046), Cryo only in 49% (n = 1,201), RF→Cryo in 6% (n = 135), and Cryo→RF in 66 (3%). Acute ablation failure occurred in 1.3% (n = 33), with no difference by energy source (1% in RF only, 1.5% in Cryo only, 1.5% in RF→Cryo, 3% in Cryo→RF; P = 0.5). Atrioventricular (AV) block requiring permanent pacemaker did not occur in any group; transient AV block occurred in 0.4% of the cohort, with no difference by group.
Conclusions:
In this largest pediatric study of AVNRT ablation, RF and Cryo demonstrated comparable high acute success and rare documentation of AV block that did not result in temporary or permanent pacing. Longitudinal data are important for further comparison of these modalities with regard to recurrence risk and late complications.
More Related Videos
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers