Effect of detector placement on joint estimation in X-ray fluorescence emission tomography
Hadley DeBrosse1, Ling Jian Meng2, Patrick La Rivière1
1Department of Radiology, University of Chicago, Chicago, IL.
Abstract:
Imaging the spatial distribution of low concentrations of metal is a growing problem of interest with applications in medical and material sciences. X-ray fluorescence emission tomography (XFET) is an emerging metal mapping imaging modality with potential sensitivity improvements and practical advantages over other methods. However, XFET detector placement must first be optimized to ensure accurate metal density quantification and adequate spatial resolution. In this work, we first use singular value decomposition of the imaging model and eigendecomposition of the object-specific Fisher information matrix to study how detector arrangement affects spatial resolution and feature preservation. We then perform joint image reconstructions of a numerical gold phantom. For this phantom, we show that two parallel detectors provide metal quantification with similar accuracy to four detectors, despite the resulting anisotropic spatial resolution in the attenuation map estimate. Two orthogonal detectors provide improved spatial resolution along one axis, but underestimate the metal concentration in distant regions. Therefore, this work demonstrates the minor effect of using fewer, but strategically placed, detectors in the case where detector placement is restricted. This work is a critical investigation into the limitations and capabilities of XFET prior to its translation to preclinical and benchtop uses.
More Related Videos
10:00Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
Published on: July 5, 2016
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...