Evaluation of vasovagal tonus index and electrocardiographic parameters in horses using a new modified base apex lead
Theerapong Pontaema1, Pongphol Pongthaisong1,2, Wootichai Kenchaiwong1,2,3
1Applied Animal Physiology Research Unit, Faculty of Veterinary Science, Mahasarakham University, Mahasarakham, 44000, Thailand.
Background And Aim:
Vasovagal tonus index (VVTI) serves as a straightforward assessment tool for autonomic function during both physiological and pathological conditions, including pregnancy, in horses. Obtaining VVTI through a modified base apex lead system could be a practical and comfortable solution. In this study, we assessed VVTI in horses with respect to training status and electrocardiographic measurements utilizing a novel modified base apex lead technique.
Materials And Methods:
A total of 12 Thai native crossbred horses and 12 Arabian horses, all free of cardiac abnormalities, were enrolled in the study. Animals underwent electrocardiogram (ECG) and VVTI using both the base-apex lead method and its modified version. 25 mm/s and 10 mm/mV ECG recordings provided standard bipolar limb leads. The amplitudes and durations of P waves, QRS complexes, PR interval, QT interval, and T duration were assessed. The T wave's shape was examined. Each recording's R-R interval was utilized to assess heart rate. Twenty consecutive beats were used to compute the variability of heart rate (VVTI).
Results:
The P wave amplitude was the only significant difference (p < 0.05) between the base apex lead method and the modified base apex lead method, with no variations in heart rate, P duration, PR interval, T duration, and QRS duration and amplitude. Both methods showed mainly biphasic T wave patterns. The VVTI values of all horses did not differ significantly between the base apex and modified base apex methods. There was no significant difference in VVTI between Thai crossbred horses and Arabian horses in either method.
Conclusion:
This study provided the first evidence that VVTI can be evaluated using the modified base apex lead system and may be useful for cardiovascular function monitoring in horses.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Electrophysiology of Normal Cardiac Rhythm
Assessment of blood pressure in brachial artery(two-step method)