Improved multi-food allergen analysis of processed foods using HRAM-LC-MS/MS with an ELISA-validated extraction
Yuriko Oyama1, Tomoko Hamasaka2, Hideki Okada3
1Morinaga BioScience, Inc., 2-1-1 Shimosueyoshi, Tsurumi-Ku, Yokohama, 230-8504, Japan.
Analytical and Bioanalytical Chemistry
|July 30, 2024
Summary
Accurate food allergen detection in processed foods is crucial. This study demonstrates that using the same food extract for enzyme-linked immunosorbent assay (ELISA) and high-resolution accurate mass spectrometry (HRAM)-LC-MS/MS ensures consistent results for multi-allergen analysis.
Area of Science:
- Food science
- Analytical chemistry
- Mass spectrometry
Background:
- Food allergens in processed foods are challenging to detect due to heating, processing, and complex food matrices.
- Reliable allergen detection requires effective extraction into test solutions for methods like ELISA and LC-MS.
- Standardized measurement values across different analytical methods are essential for food manufacturing allergen management.
Purpose of the Study:
- To investigate the critical role of pretreatment steps in LC-MS analysis of food allergens in processed foods.
- To develop and validate a high-resolution accurate mass spectrometry (HRAM)-LC-MS/MS method for multi-allergen detection.
- To ensure comparability of results between established ELISA methods and novel LC-MS techniques.
Main Methods:
- Utilized food extracts optimized for ELISA for subsequent HRAM-LC-MS/MS analysis.
- Employed an MS sample preparation kit for sample processing.
- Performed multi-allergen analysis on processed foods spiked with allergens at concentrations of 1, 5, 10, and 20 ppm.
Main Results:
- A strong correlation was observed between measured values obtained from HRAM-LC-MS/MS and ELISA.
- The developed HRAM-LC-MS/MS method proved effective for analyzing multiple food allergens simultaneously.
- The study confirmed the applicability of LC-MS for reliable food allergen quantification in processed food matrices.
Conclusions:
- Standardized food extracts and pretreatment protocols enable consistent allergen quantification across ELISA and HRAM-LC-MS/MS.
- HRAM-LC-MS/MS offers a viable and accurate alternative for multi-allergen detection in processed foods.
- This research supports the integration of advanced LC-MS techniques for robust food allergen management systems.