Mitigating data quality challenges in ambulatory wrist-worn wearable monitoring through analytical and practical
Jonas Van Der Donckt1, Nicolas Vandenbussche2,3, Jeroen Van Der Donckt4
1IDLab, Ghent University - Imec, Technologiepark-Zwijnaarde, 9052, Ghent, Belgium. Jonvdrdo.VanDerDonckt@UGent.be.
Abstract:
Chronic disease management and follow-up are vital for realizing sustained patient well-being and optimal health outcomes. Recent advancements in wearable technologies, particularly wrist-worn devices, offer promising solutions for longitudinal patient monitoring, replacing subjective, intermittent self-reporting with objective, continuous monitoring. However, collecting and analyzing data from wearables presents several challenges, such as data entry errors, non-wear periods, missing data, and wearable artifacts. In this work, we explore these data analysis challenges using two real-world datasets (mBrain21 and ETRI lifelog2020). We introduce practical countermeasures, including participant compliance visualizations, interaction-triggered questionnaires to assess personal bias, and an optimized pipeline for detecting non-wear periods. Additionally, we propose a visualization-oriented approach to validate processing pipelines using scalable tools such as tsflex and Plotly-Resampler. Lastly, we present a bootstrapping methodology to evaluate the variability of wearable-derived features in the presence of partially missing data segments. Prioritizing transparency and reproducibility, we provide open access to our detailed code examples, facilitating adaptation in future wearable research. In conclusion, our contributions provide actionable approaches for improving wearable data collection and analysis.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.