AutoCorNN: An Unsupervised Physics-Aware Deep Learning Model for Geometric Distortion Correction of Brain MRI Images
Mahboube Sadat Hosseini1, Seyed Mahmoud Reza Aghamiri2, Ali Fatemi Ardekani3,4
1Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, 1983969411, Iran.
Abstract:
Geometric distortions in brain MRI images arising from susceptibility artifacts at air-tissue interfaces pose a significant challenge for high-precision radiation therapy modalities like stereotactic radiosurgery, necessitating sub-millimeter accuracy. To achieve this goal, we developed AutoCorNN, an unsupervised physics-aware deep-learning model for correcting geometric distortions. Two publicly available datasets, the MPI-Leipzig Mind-Brain-Body with 318 subjects, and the Vestibular Schwannoma-SEG dataset, encompassing 242 patients were utilized. AutoCorNN integrates two 2D convolutional encoder-decoder neural networks with the forward physical model of MRI signal generation to predict undistorted MR and field map images from distorted MR input. The network is trained in an unsupervised manner by minimizing the mean absolute error between the measured and estimated k-space data, without requiring ground truth images during training or deployment. The model was evaluated on vestibular schwannoma cases. AutoCorNN achieved a peak signal-to-noise ratio (PSNR) of 41.35 ± 0.02 dB, a root mean square error (RMSE) of 0.02 ± 0.003, and a structural similarity index (SSIM) of 0.99 ± 0.02 outperforming uncorrected and B0-mapping correction methods. Geometric distortions of about 1.6 mm were observed at the air-tissue interfaces at the air canal and nasal cavity borders. Geometrically, distortion correction increased the target volume from 3.12 ± 0.52 cc to 3.84 ± 0.54 cc. Dosimetrically, AutoCorNN improved target coverage (0.96 ± 0.01 to 0.97 ± 0.02), conformity index (0.92 ± 0.03 to 0.94 ± 0.03), and reduced dose gradients outside the target. AutoCorNN achieves accurate geometric distortion correction comparable to conventional iterative methods while offering substantial computational acceleration, enabling precise target delineation and conformal dose delivery for improved radiation therapy outcomes.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging