Effect of standardized EHR-integrated handoff report on intraoperative communication outcomes
Joanna Abraham1,2, Christopher R King1, Lavanya Pedamallu1
1Department of Anesthesiology, Washington University School of Medicine, St Louis, MO 63110, United States.
Objectives:
We evaluated the effectiveness and implementability of a standardized EHR-integrated handoff report to support intraoperative handoffs.
Materials And Methods:
A pre-post intervention study was used to compare the quality of intraoperative handoffs supported by unstructured notes (pre) to structured, standardized EHR-integrated handoff reports (post). Participants included anesthesia clinicians involved in intraoperative handoffs. A mixed-method approach was followed, supported by general observations, shadowing, surveys, and interviews.
Results:
One hundred and fifty-one intraoperative permanent handoffs (78 pre, 73 post) were included. One hundred percent of participants in the post-intervention cohort utilized the report. Compared to unstructured, structured handoffs using the EHR-integrated handoff report led to: (1) significant increase in the transfer of information about airway management (55%-78%, P < .001), intraoperative course (63%-86%, P < .001), and potential concerns (64%-88%, P < .001); (2) significant improvement in clinician satisfaction scores, with regards to information clarity and succinctness (4.5-4.7, P = .002), information transfer (3.8-4.2, P = .011), and opportunities for fewer errors reported by senders (3.3-2.5, P < .001) and receivers (3.2-2.4, P < .001); and (3) significant decrease in handoff duration (326.2-262.3 s, P = .016). Clinicians found the report implementation highly acceptable, appropriate, and feasible but noted a few areas for improvement to enhance its usability and integration within the intraoperative workflow.
Discussion And Conclusion:
A standardized EHR-integrated handoff report ensures the effectiveness and efficiency of intraoperative handoffs with its structured, consistent format that-promotes up-to-date and pertinent intraoperative information transfer; reduces opportunities for errors; and streamlines verbal communication. Handoff standardization can promote safe and high-quality intraoperative care.
Related Concept Videos
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
SBAR I: Understanding the Concept
Standardized methods of communication have been developed to ensure that information is...
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Role of Communication in the Nursing Process III: Evaluation and Documentation
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...