Related Experiment Video
Updated: May 7, 2026

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Long-Term Effects of Pulmonary Valve Implantation and Prosthesis Evolution in Patients with Repaired Tetralogy of
Luiz Fernando Caneo1, Aida Luiza Ribeiro Turquetto1, Matheus Negri Boschiero2
1Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
Background:
Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF).
Objective:
This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position.
Methods:
A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI.
Results:
After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8).
Conclusion:
As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis III: Medical Management
Mitral Stenosis IV: Nursing Management