Interprofessional Evaluation of a Medication Clinical Decision Support System Prior to Implementation
Jacqueline Bauer1, Marika Busse1, Tanja Kopetzky2
1Pharmacy Department, Universitätsklinikum Erlangen and Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Background:
Computerized physician order entry (CPOE) and clinical decision support systems (CDSS) are widespread due to increasing digitalization of hospitals. They can be associated with reduced medication errors and improved patient safety, but also with well-known risks (e.g., overalerting, nonadoption).
Objectives:
Therefore, we aimed to evaluate a commonly used CDSS containing Medication-Safety-Validators (e.g., drug-drug interactions), which can be locally activated or deactivated, to identify limitations and thereby potentially optimize the use of the CDSS in clinical routine.
Methods:
Within the implementation process of Meona (commercial CPOE/CDSS) at a German University hospital, we conducted an interprofessional evaluation of the CDSS and its included Medication-Safety-Validators following a defined algorithm: (1) general evaluation, (2) systematic technical and content-related validation, (3) decision of activation or deactivation, and possibly (4) choosing the activation mode (interruptive or passive). We completed the in-depth evaluation for exemplarily chosen Medication-Safety-Validators. Moreover, we performed a survey among 12 German University hospitals using Meona to compare their configurations.
Results:
Based on the evaluation, we deactivated 3 of 10 Medication-Safety-Validators due to technical or content-related limitations. For the seven activated Medication-Safety-Validators, we chose the interruptive option ["PUSH-(&PULL)-modus"] four times (4/7), and a new, on-demand option ["only-PULL-modus"] three times (3/7). The site-specific configuration (activation or deactivation) differed across all participating hospitals in the survey and led to varying medication safety alerts for identical patient cases.
Conclusion:
An interprofessional evaluation of CPOE and CDSS prior to implementation in clinical routine is crucial to detect limitations. This can contribute to a sustainable utilization and thereby possibly increase medication safety.
More Related Videos
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Preclinical Development: Overview
Methods of Documentation III: PIE