Abstract:
We investigated the techno-economic feasibility and power supply potential of enhanced geothermal systems (EGS) across the contiguous United States using a new subsurface temperature model and detailed simulations of EGS project life cycle. Under business-as-usual scenarios and across depths of 1-7 kilometers, we estimated 82,945 GW and 0.65 GW of EGS supply capacity with lower levelized cost of electricity than conventional hydrothermal and solar photovoltaic projects, respectively. Considering the scenario of flexible geothermal dispatch via wellhead throttling and power plant bypass, these estimates climbed up to 184,112 GW and 44.66 GW, respectively. The majority of EGS supply potential was found in the Western and Southwestern regions of the United States, where California, Oregon, Nevada, Montana, and Texas had the greatest EGS capacity potential. With advanced drilling rates based on state-of-the-art implementations of recent EGS projects, we estimated an average improvement of 25.1% in the levelized cost of electricity. These findings underscored the pivotal role of flexible operations in enhancing the competitiveness and scalability of EGS as a dispatchable renewable energy source.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
00:13Using Flexible Gold-Titanium Reaction Cells to Simulate Pressure-Dependent Microbial Activity in the Context of Subsurface Biomining
Published on: October 5, 2019
Related Concept Videos
Control of Power Flow
Load-frequency control
Turbine-Governor Control
Generator Voltage Control
Power in a Three-Phase Circuit
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...